Support |
On Jul 10, 2005, at 11:57, Hartung, Kris wrote: > Before I start troubleshooting in detail, I thought I would try > resetting the FCB to factory state first. However, I am confused by > what > the manual says about this. It shows three ways to perform a factory > reset: V-AMP family products, BEHRINGER guitar amps, and BASS V-AMP > product range. Is there a particular reset option I should choose? No. Whatever reset you use you will have to empty the banks and put in new data for the EDP. When programming your FCB banks you must be aware of that the FCB can send multiple midi commands on every button press. In the FCB patch programming mode you have to disable everything except for what the EDP needs. Otherwise you will go nuts when trying to get it right ;-) Greetings from Sweden Per Boysen www.looproom.com (international) www.boysen.se (Swedish) ---> iTunes Music Store (digital) www.cdbaby.com/perboysen