Re: Electro-harmonic Superego



>From this test, the circuit is closed when the switch is pressed down.
 So that replacement should be good, right?
Sylvain


On Tue, Mar 12, 2013 at 4:49 PM, andy butler <akbutler@tiscali.co.uk> 
wrote:
> A bag of clues :-)
> ..probably more than you need.
>
> Analog meter is nicer than digital for this job.
>
> We're just checking for whether there a connection or not.
>
> Set meter to read Resistance, ( Ohms )
> If there's more than one option for this then doesn't matter
> which.
>
> Note what happens when you touch the probes together.
> (Meter swings across showing you have a connection)
>
> Open Freeze, locate the two tags on the switch which have wires going to
> them.
> Place one probe on each of those...note reading.
> Hold down switch and repeat.
>
> Share observations/conclusions.
>
> andy
>
>
>
>
>
> Sylvain Poitras wrote:
>>
>> On Tue, Mar 12, 2013 at 6:00 AM, andy butler <akbutler@tiscali.co.uk>
>> wrote:
>>>
>>> Someone out there with a Freeze has to open it up and put a meter 
>>> across
>>> the
>>> existing switch.
>>
>>
>> Well, I have a Freeze and an analog meter, but no clue...
>> Sylvain
>>
>>
>