Re: EDP, DirectMIDI, quant, 8ths



hi Phil,
glad you got the sysex working.

A couple of hints

1) while processing a sysex command the edp doesn't have the processing 
power
to do anything else. That includes checking for midi input.
If you need to change more than one param with a sysex command
you'll have to use a midi controller that puts a delay between them.
The audio from the edp will drop out briefly while processing sysex.

2) Changes to 8th/Cycle aren't effective till the end of the cycle
(or is it end of the loop?)
andy butler
(back from holiday)


Phil Clevenger wrote:
Mark, and Per,

Yes, Program Changes for EDP preset changes are the basis for the controller setup. But I find there are too many permutations